Memory Map

Device Name Start Address End Address
DDR Low 0x00000000 0x7FFFFFFF
M_AXI_HPM0_LPD (LPD_PL) 0x80000000 0x9FFFFFFF
VCU Encoder 0xA0000000  
VCU Decoder 0xA0020000  
VCU System-Level Control 0xA0040000  
M_AXI_HPM0_FPD (HPM0) interface(1) 0xA4000000 0xAFFFFFFF
M_AXI_HPM1_FPD (HPM1) interface 0xB0000000 0xBFFFFFFF
Quad-SPI 0xC0000000 0xDFFFFFFF
PCIe Low 0xE0000000 0xEFFFFFFF
Reserved 0xF0000000 0xF7FFFFFF
128 MB reserved 0xF0000000 0xF7FFFFFF
STM CoreSight 0xF8000000 0xF8FFFFFF
APU GIC 0xF9000000 0xF90FFFFF
GIC distributor. 0xF9000000 0xF9001FFF
APU GIC Interrupt Controller; GICv2 0xF9000000  
RPU GIC Interrupt Controller; GICv1 0xF9000000  
GICC interface. 0xF9002000 0xF9002FFF
Reserved 0xF9100000 0xFCFFFFFF
63 MB reserved 0xF9100000 0xFCFFFFFF
FPD devices 0xFD000000 0xFDFFFFFF
Memory Protection Unit (XMPU) 0 Configuration 0xFD000000  
Memory Protection Unit (XMPU) 1 Configuration 0xFD010000  
Memory Protection Unit (XMPU) 2 Configuration 0xFD020000  
Memory Protection Unit (XMPU) 3 Configuration 0xFD030000  
Memory Protection Unit (XMPU) 4 Configuration 0xFD040000  
Memory Protection Unit (XMPU) 5 Configuration 0xFD050000  
DDR controller 0xFD070000  
DDR Memory Controller 0xFD070000  
DDR PHY 0xFD080000  
DDR PHY Register Description, DDR PHY Control 0xFD080000  
DDR QoS control 0xFD090000  
DDR QoS Control 0xFD090000  
Arm for DDR 0xFD0B0000  
AXI DDR Performance Monitor 0xFD0B0000  
SATA registers (HBA, vendor, port-0/1 control) 0xFD0C0000  
SATA AHCI HBA Spec 0xFD0C0000  
SATA AHCI Vendor 0xFD0C00A0  
SATA AHCI Port 0 Control 0xFD0C0100  
SATA AHCI Port 1 Control 0xFD0C0180  
AXI PCIe bridge 0xFD0E0000  
PCIe Bridge - Main Control and Status 0xFD0E0000  
AXI PCIe ingress {0:7} 0xFD0E0800  
PCIe Bridge - Ingress Addr Translation 0 0xFD0E0800  
PCIe Bridge - Ingress Addr Translation 1 0xFD0E0820  
PCIe Bridge - Ingress Addr Translation 2 0xFD0E0840  
PCIe Bridge - Ingress Addr Translation 3 0xFD0E0860  
PCIe Bridge - Ingress Addr Translation 4 0xFD0E0880  
PCIe Bridge - Ingress Addr Translation 5 0xFD0E08A0  
PCIe Bridge - Ingress Addr Translation 6 0xFD0E08C0  
PCIe Bridge - Ingress Addr Translation 7 0xFD0E08E0  
AXI PCIe egress {0:7} 0xFD0E0C00  
PCIe Bridge - Egress Addr Translation 0 0xFD0E0C00  
PCIe Bridge - Egress Addr Translation 1 0xFD0E0C20  
PCIe Bridge - Egress Addr Translation 2 0xFD0E0C40  
PCIe Bridge - Egress Addr Translation 3 0xFD0E0C60  
PCIe Bridge - Egress Addr Translation 4 0xFD0E0C80  
PCIe Bridge - Egress Addr Translation 5 0xFD0E0CA0  
PCIe Bridge - Egress Addr Translation 6 0xFD0E0CC0  
PCIe Bridge - Egress Addr Translation 7 0xFD0E0CE0  
AXI PCIe DMA {0:7} 0xFD0F0000  
PCIe Bridge - DMA Channel 0 0xFD0F0000  
PCIe Bridge - DMA Channel 1 0xFD0F0080  
PCIe Bridge - DMA Channel 2 0xFD0F0100  
PCIe Bridge - DMA Channel 3 0xFD0F0180  
CRF_APB 0xFD1A0000  
Clock and Reset control registers for FPD. 0xFD1A0000  
QoS and FIFO Configuration 0xFD360000  
S_AXI_HPC1_FPD QoS and FIFO Configuration 0xFD370000  
S_AXI_HP0_FPD QoS and FIFO Configuration 0xFD380000  
S_AXI_HP1_FPD QoS and FIFO Configuration 0xFD390000  
S_AXI_HP2_FPD QoS and FIFO Configuration 0xFD3A0000  
S_AXI_HP3_FPD QoS and FIFO Configuration 0xFD3B0000  
SerDes Control and Debug 0xFD3D0000  
SerDes Configuration 0xFD400000  
PCIe Controller Attributes 0xFD480000  
CCI APM Control and Configuration 0xFD490000  
DisplayPort Controller 0xFD4A0000  
GPU with two pixel processors, Graphics Processing Unit 0xFD4B0000  
DisplayPort DMA 0xFD4C0000  
FPD_SWDT, system watchdog timer (swdt1) 0xFD4D0000  
XMPU_Sink (FPD) 0xFD4F0000  
FPD_DMA channels {0:7} 0xFD500000  
FPD DMA Channel 0 0xFD500000  
FPD DMA Channel 1 0xFD510000  
FPD DMA Channel 2 0xFD520000  
FPD DMA Channel 3 0xFD530000  
FPD DMA Channel 4 0xFD540000  
FPD DMA Channel 5 0xFD550000  
FPD DMA Channel 6 0xFD560000  
FPD DMA Channel 7 0xFD570000  
APU settings, APU Configuration 0xFD5C0000  
FPD XMPU Configuration 0xFD5D0000  
AXI Cache Coherent Interconnect Configuration 0xFD5E0000  
SMMU_REG (interrupts, power, and unit control) 0xFD5F0000  
FPD System-level Control 0xFD610000  
FPD System-level Control - Secure 0xFD690000  
CCI_GPV (CCI400, parameters) 0xFD6E0000  
FPD_GPV (parameters) 0xFD700000  
SMMU_GPV (SMMU500, parameters) 0xFD800000  
Upper LPD devices 0xFE000000 0xFEFFFFFF
IOU_GPV (parameters) 0xFE000000  
LPD_GPV (parameters) 0xFE100000  
USB Port 0 XHCI 0xFE200000  
USB Port 1 XHCI 0xFE300000  
CoreSight top level ROM in DAP, DAP ROM 0xFE800000  
Master Timestamp generator 0xFE900000  
Funnel for multiple trace streams to single ATB 0xFE910000  
Funnel for multiple trace streams to single ATB 0xFE920000  
Funnel for multiple trace streams to single ATB 0xFE930000  
Embedded Trace FIFO 0xFE940000  
Embedded Trace FIFO 0xFE950000  
Replicator forks ATB data to multiple streams 0xFE960000  
Embedded Trace Router 0xFE970000  
Test Port Interface Unit bridge to on-chip trace data 0xFE980000  
SoC Cross Trigger Interface with to/from broadcast 0xFE990000  
SoC Cross Trigger Interface with to/from broadcast 0xFE9A0000  
SoC Cross Trigger Interface with to/from broadcast 0xFE9B0000  
System Trace Macrocell 0xFE9C0000  
Fabric Trigger Macrocell interface from PL to ECT 0xFE9D0000  
R5 Integration ROM 0xFEBE0000  
Cortex-R5 built-in debug logic, R5 Debug Logic 0xFEBF0000  
Cortex-R5 built-in debug logic, R5 Debug Logic 0xFEBF2000  
R5 Cross Trigger Interface with to/from broadcast 0xFEBF8000  
R5 Cross Trigger Interface with to/from broadcast 0xFEBF9000  
R5 Embedded Trace Macrocell 0xFEBFC000  
A53 Integration ROM 0xFEC00000  
Cortex-A53 built-in debug logic, A53 Debug Logic 0xFEC10000  
A53 Cross Trigger Interface with to/from broadcast 0xFEC20000  
A53 Performance Monitor Unit profiler 0xFEC30000  
A53 Embedded Trace Macrocell 0xFEC40000  
Cortex-A53 built-in debug logic, A53 Debug Logic 0xFED10000  
A53 Cross Trigger Interface with to/from broadcast 0xFED20000  
A53 Performance Monitor Unit profiler 0xFED30000  
A53 Embedded Trace Macrocell 0xFED40000  
Cortex-A53 built-in debug logic, A53 Debug Logic 0xFEE10000  
A53 Cross Trigger Interface with to/from broadcast 0xFEE20000  
A53 Performance Monitor Unit profiler 0xFEE30000  
A53 Embedded Trace Macrocell 0xFEE40000  
Cortex-A53 built-in debug logic, A53 Debug Logic 0xFEF10000  
A53 Cross Trigger Interface with to/from broadcast 0xFEF20000  
A53 Performance Monitor Unit profiler 0xFEF30000  
A53 Embedded Trace Macrocell 0xFEF40000  
Lower LPD devices 0xFF000000 0xFFBFFFFF
UART 0 Controller 0xFF000000  
UART 1 Controller 0xFF010000  
I2C 0 Controller 0xFF020000  
I2C 1 Controller 0xFF030000  
SPI 0 Controller 0xFF040000  
SPI 1 Controller 0xFF050000  
CAN 0 Controller 0xFF060000  
CAN 1 Controller 0xFF070000  
GPIO Controller 0xFF0A0000  
Gigabit Ethernet; GEM 0 Controller 0xFF0B0000  
Gigabit Ethernet; GEM 1 Controller 0xFF0C0000  
Gigabit Ethernet; GEM 2 Controller 0xFF0D0000  
Gigabit Ethernet; GEM 3 Controller 0xFF0E0000  
Quad SPI Controller 0xFF0F0000  
NAND ONFI Control 0xFF100000  
Triple Timer Counter 0 0xFF110000  
Triple Timer Counter 1 0xFF120000  
Triple Timer Counter 2 0xFF130000  
Triple Timer Counter 3 0xFF140000  
LPD_SWDT, system watchdog timer (swdt0) 0xFF150000  
LPD System Watchdog Timer 0xFF150000  
SD0 0xFF160000  
SDIO 0 Controller 0xFF160000  
SD1 0xFF170000  
SDIO 1 Controller 0xFF170000  
IOU_SLCR 0xFF180000  
IOP System-level Control 0xFF180000  
IOU_SECURE_SLCR 0xFF240000  
IOP System-level Control - Secure 0xFF240000  
System Timestamp Generator 0xFF250000  
IOU_SCNTRS 0xFF260000  
System Timestamp Generator - Secure 0xFF260000  
Inter-processor interrupts (IPI) 0xFF300000  
Inter-Processor Interrupts Control and Status 0xFF300000  
LPD_SLCR 0xFF410000  
Low-power Domain System-level Control Registers 0xFF410000  
LPD_SLCR_SECURE 0xFF4B0000  
Low-power Domain System-level Control Registers - Secure 0xFF4B0000  
CRL_APB 0xFF5E0000  
Clock and Reset control registers for LPD. 0xFF5E0000  
OCM Memory Controller Configuration 0xFF960000  
XPPU (Xilinx peripheral protection unit) 0xFF980000  
XPPU Configuration 0xFF980000  
IPI message buffer memory; see Table 13-3. 0xFF990000  
Realtime Processing Unit, Real time Processing Unit 0xFF9A0000  
PL_LPD (S_AXI_LPD) 0xFF9B0000  
QoS and FIFO Configuration for seven PL to PS AXI interfaces. 0xFF9B0000  
XPPU Sink Controller 0xFF9C0000  
USB Core 0 Controller 0xFF9D0000  
USB Core 1 Controller 0xFF9E0000  
Arm for OCM interconnect 0xFFA00000  
OCM Performance Monitor 0xFFA00000  
Arm for LPD to FPD interconnect 0xFFA10000  
LPD Performance Monitor 0xFFA10000  
System monitor register sets (AMS) 0xFFA50000  
PS/PL SysMon Units Control and Status 0xFFA50000  
System monitor register sets (PSSYSMON) 0xFFA50800  
PS System Monitor 0xFFA50800  
System monitor register sets (PLSYSMON) 0xFFA50C00  
PL System Monitor 0xFFA50C00  
Real-time clock (RTC) 0xFFA60000  
Real Time Clock Control and Configuration 0xFFA60000  
OCM_XMPU 0xFFA70000  
OCM Memory Protection Unit Configuration 0xFFA70000  
LPD_DMA channels {0:7} 0xFFA80000  
LPD DMA Channel 0 0xFFA80000  
LPD DMA Channel 1 0xFFA90000  
LPD DMA Channel 2 0xFFAA0000  
LPD DMA Channel 3 0xFFAB0000  
LPD DMA Channel 4 0xFFAC0000  
LPD DMA Channel 5 0xFFAD0000  
LPD DMA Channel 6 0xFFAE0000  
LPD DMA Channel 7 0xFFAF0000  
CSU, PMU, TCM, OCM 0xFFC00000 0xFFFFFFFF
CSU_ROM 0x00FFC00000 0x00FFC1FFFF
CSU_RAM 0x00FFC40000 0x00FFC47FFF
CSU module DMA Engine, CSU DMA Control 0xFFC80000  
Configuration and security unit (CSU) 0xFFCA0000  
CSU_SWDT, system watchdog timer (csu_pmu_wdt). 0xFFCB0000  
eFUSE Control 0xFFCC0000  
Battery-backed RAM (BBRAM) control and data 0xFFCD0000  
RSA Core Data and Configuration 0xFFCE0000  
RSA Data and Configuration 0xFFCE002C  
PMU_ROM 0x00FFD00000 0x00FFD3FFFF
PMU IO Module - Private 0xFFD40000  
PMU Local Control - Private 0xFFD60000  
PMU Global Control 0xFFD80000  
PMU_RAM 0x00FFDC0000 0x00FFDDFFFF
R5_0_ATCM_SPLIT 0x00FFE00000 0x00FFE0FFFF
R5_0_ATCM_LSTEP 0x00FFE00000 0x00FFE1FFFF
R5_0_BTCM_SPLIT 0x00FFE20000 0x00FFE2FFFF
R5_0_BTCM_LSTEP 0x00FFE20000 0x00FFE3FFFF
R5_0_ICACHE 0x00FFE40000 0x00FFE4FFFF
R5_0_DCACHE 0x00FFE50000 0x00FFE5FFFF
R5_1_ATCM_SPLIT 0x00FFE90000 0x00FFE9FFFF
R5_1_BTCM_SPLIT 0x00FFEB0000 0x00FFEBFFFF
R5_1_ICACHE 0x00FFEC0000 0x00FFECFFFF
R5_1_DCACHE 0x00FFED0000 0x00FFEDFFFF
OCM_RAM 0x00FFFC0000 0x00FFFFFFFF
Reserved 0x0100000000 0x03FFFFFFFF
M_AXI_HPM0_FPD (HPM0) 0x0400000000 0x04FFFFFFFF
M_AXI_HPM1_FPD (HPM1) 0x0500000000 0x05FFFFFFFF
PCIe High 0x0600000000 0x07FFFFFFFF
DDR High 0x0800000000 0x0FFFFFFFFF
M_AXI_HPM0_FPD (HPM0) 0x1000000000 0x47FFFFFFFF
M_AXI_HPM1_FPD (HPM1) 0x4800000000 0x7FFFFFFFFF
PCIe High 0x8000000000 0xBFFFFFFFFF
Reserved 0xC000000000 0xFFFFFFFFFF

Reference

The Xilinx graphic is from [link]